Timestamp fields
event_time_utc records when the reported event occurred. received_at_utc records when that provider record entered the database.
Reference rules for interpreting the frozen database. These are provider conventions, not case answers.
event_time_utc records when the reported event occurred. received_at_utc records when that provider record entered the database.
For terminal assignment: current terminal nomination, then confirmed port call, then declared AIS destination. AIS text alone is non-binding and may be stale.
IMO plus voyage ID is the primary cargo key. Repeated reports from multiple feeds do not represent additional physical cargoes.
European terminal gas days begin at 06:00 local terminal time. Provider arrival timestamps are UTC; standard sendout starts on the arrival gas day unless an operational constraint prevents it.
Unless a terminal notice overrides timing, allocate the cargo energy to regasification sendout as 20% on Day 0, 50% on Day 1, and 30% on Day 2.
Discharge adds LNG energy to terminal tank inventory. Regasification sendout removes it from terminal inventory and is the LNG supply flow into the gas system; the two dates may differ when operations constrain sendout.
The balance convention uses 10.8 GWh per mcm. This reference package does not publish an m³ LNG-to-energy conversion; do not manufacture one.
When equal-precedence records conflict and no tie-break is published, retain both observations and mark the operational result unresolved.